An EICR is the electrical equivalent of an MOT for a property. We inspect and test the fixed wiring — the consumer unit, the circuits, the sockets, switches and lights — and give you a report that says whether it's safe to keep using and what, if anything, needs doing.

Who needs an EICR

What happens on the day

We start with a visual inspection of the consumer unit and the installation, then test each circuit with calibrated instruments: earthing and bonding, insulation resistance, polarity, earth-fault loop impedance and RCD operation. Some tests need the power off for short periods, so a typical house takes one to three hours depending on its size and how many circuits there are. You, or a tenant or keyholder, needs to let us in and give access to the consumer unit and the rooms. Nothing is taken apart that doesn't go back together.

Understanding the result

Every observation on the report gets a code. The outcome is Satisfactory unless there's a C1 or C2 on it, in which case it's Unsatisfactory until those are put right. Since Amendment 4 of BS 7671 (2026) an FI on its own no longer makes a report Unsatisfactory — it still needs following up, but it doesn't fail the installation.

The Codes

What C1, C2, C3 and FI mean

C1

Danger present

Risk of injury right now — exposed live parts, for example. We make it safe before we leave, and tell you what's needed to fix it properly.

C2

Potentially dangerous

Not an immediate danger, but could become one. Needs urgent remedial work to bring the report to Satisfactory.

C3

Improvement recommended

Not dangerous and doesn't fail the report, but worth doing — typically things that were fine when installed and have since changed in the regulations.

FI

Further investigation

Something we couldn't fully establish on the day without more access or time. Further investigation is advised. Under Amendment 4 (2026) an FI alone doesn't make the report Unsatisfactory, but we tell you exactly what it would take to clear it.

Remedial work

If the report comes back Unsatisfactory — a C1 or C2 on it — we quote the remedials separately, so you can see the cost of each item and decide. Once the work is done you get the certificate for it and a note confirming the installation is now Satisfactory. We're also happy to carry out remedials from another company's EICR — send us the report and we'll price it.

Pricing

EICRs are a fixed price, set by the size of the property and the number of consumer units, so you know the cost before we book the visit. No VAT is added.

PropertyPrice
Studio or one-bedroom flat£185
Two-bedroom flat£200
Three-bedroom flat or two-bedroom house£215
Three-bedroom house£240
Four-bedroom house£280
Five-bedroom house£320
Each extra consumer unit (up to 6-way)+ £150
Each extra consumer unit (7 to 10-way)+ £180

Each price includes one consumer unit and its circuits, with £10 for each circuit over the usual number for that size of property. Park homes, HMOs and businesses are priced on the boards and circuits; tell us the address and you'll have the exact figure back the same day. Travel is one flat charge per visit: nothing for Llandudno, Conwy and Colwyn Bay, £10 for the Conwy Valley, £15 for Abergele and Rhyl or Bangor and Caernarfon, and £25 for Anglesey. Landlords with several properties can ask for a portfolio rate, and we can schedule a block of inspections so the whole lot is renewed in one go.

Estimate your price

Answer four quick questions for a price range. It's an estimate, not a quote. You get a fixed price before anything is booked.

The estimator needs JavaScript. Call 07947 809008 or ask for a price instead.

What you get

Done properly. BlueForge is NVQ qualified, holds the 2391 inspection and testing qualification, is insured, uses calibrated test instruments, and issues reports to the current BS 7671:2018+A4:2026 model forms.
NVQ Level 3 Electrician 18th Edition — BS 7671 (A4:2026) 2391 Inspection & Testing Public liability insured Calibrated test instruments 10+ years with rental & holiday properties

Need an EICR booked in?

Common Questions

Frequently asked questions

How often does a rented property need an EICR?

In Wales, at least every five years under the Renting Homes (Wales) Act, or sooner if the previous report says so. A new report is also needed when a property is first let.

How long does an EICR take?

Usually one to three hours for a house or flat, depending on size and the number of circuits. Larger or older properties and commercial premises take longer. We'll give you a time when we quote.

Does the power have to go off?

Yes, briefly, for some of the tests. We tell whoever is in the property before we start and keep the interruptions short. Fridges and freezers are fine.

Does the tenant need to be there?

Someone needs to let us in and give access to the consumer unit and each room — a tenant, keyholder or agent is fine. We work around tenants and let you know when we're done.

What if the report is Unsatisfactory?

We send the report with the codes explained and a separate itemised quote for the remedial work. Once that's done, the installation is confirmed as Satisfactory and you have the paperwork to show for it.

Is an EICR a certificate?

Strictly it's a report, not a certificate — but it's the document landlords, agents, insurers and licensing officers mean when they ask for an electrical safety certificate.

Do you do EICRs on park homes and static caravans?

Yes. We cover park homes and lodges across Anglesey and North Wales and understand the site supply arrangements. Site owners often ask for one at sale or on a fixed cycle.